Power Top

SYMPTOM
* INOPERATIVE POWER TOP MOTOR

POSSIBLE CAUSES
- Fused ignition switch output circuit open
- PDC defective - fused ignition switch output
- Power top inhibit relay control circuit open
- Power top inhibit relay output circuit open
- Power top inhibit relay defective - coil open
- BCM defective relay control function
- Problem not with feed CKT to power top switch