Variable Induction Control Actuator: Service and Repair
REMOVAL 1.
Remove the negative battery cable.
2.
Remove link.
3.
Remove electrical connector.
4.
Remove 3 bolts.
Fig.24 Short Runner Value (SRV):
5.
Remove valve (Fig. 24).
INSTALLATION 1.
Install 3 bolts and tighten to
6.7 N.m (60 in.lbs.). 2.
Install link.
3.
Install electrical connector.
4.