Installation






INSTALLATION





1. Install a new rubber grommet seal into the washer fluid level switch mounting hole in the washer reservoir (1). Always use a new rubber grommet seal on the reservoir.

2. Insert the nipple formation of the washer fluid level switch (5) through the rubber grommet seal in the reservoir.

3. Using hand pressure, press firmly and evenly on the switch mounting flange until the barbed nipple is fully seated in the rubber grommet seal in the reservoir. The flat edge of the switch mounting flange should be oriented downward.

4. Reconnect the wire harness connector to the switch connector receptacle.

5. Reconnect the front washer hose to the inboard outlet nipple (3) of the washer pump/motor unit (2).

6. Refill the washer reservoir with the washer fluid drained from the reservoir during the removal procedure.

7. Reconnect the battery negative cable.