Flushing Condenser, Liquid and Discharge Hose
Refer to figure 4
1. Disconnect the discharge line at the compressor, using care not to ruin original gasket.
2. Attach flushing adapter, Special Tool # 6005, to discharge line at compressor end using two 5/16" x 2" bolts, four 5/16" flat washers, and two 5/16" nuts.
3. Place the condenser discharge end of the liquid line, normally attached to the filter drier, into a suitable container to collect the flushing compound.
4. Attach one can of flushing compound, PN 4318008, using appropriate can tapper or refrigerant manifold and charging hose, to the flushing adapter.
5. Turn and hold can of flushing compound upside down, and discharge one can through the condenser liquid and discharge hose.
6. Blow out remaining flushing compound from system components, using R-12 or similar "dry" air source.
NOTE:
DO NOT USE NORMAL COMPRESSED "SHOP" AIR AS IT CONTAINS MOISTURE WHICH MAY CONTAMINATE SYSTEM.
7. Remove flushing adapter and save old gasket for use in flushing compressor.