Using Choke Valve Angle Gauge
Fig. 10 Using choke valve angle gauge:
1. Close choke valve.
2. Rotate degree scale until zero is opposite pointer, Fig. 10.
3. Center leveling bubble.
4. Rotate scale to specified angle.
5. Adjust linkage to center bubble.