High Pressure Sensor / Switch: Testing and Inspection
Before performing diagnosis of the high pressure cut-off switch, verify that the refrigerant system has the correct refrigerant charge.1. Disconnect and isolate the battery negative cable.
2. Unplug the wire harness connector from the high pressure cut-off switch on the refrigerant system fitting.