Operation CHARM: Car repair manuals for everyone.

Coolant Vacuum Switch Cold Open (CVSCO) Test


1. Check vacuum hoses for correct routing and installation.
2. With valve installed, disconnect molded connector from valve. Connect a 1/8 inch inside diameter hose to bottom port of valve.
3. With radiator top tank warm (no warmer than 75° F), blow through hose. If it is not possible to blow through hose, replace valve.
4. Operate engine until normal operating temperature is obtained.
5. Connect a suitable vacuum pump and gauge No. C-4207 or equivalent, to bottom port of valve. Apply 10 inches Hg vacuum to the valve. If vacuum level drops more than one inch in 15 seconds, replace valve.