Operation CHARM: Car repair manuals for everyone.

Transmission Temperature Sensor/Switch: Testing and Inspection





CONTINUITY CHECK
1. Disconnect the transaxle range sensor connector.
2. Measure the resistance between terminals 2-3 and check that the values are as shown below.
Standard values:
Oil temperature: 0 °C (32 °F)
Resistance value: 29.33 - 35.99 k ohms
Oil temperature: 100 °C (212 °F)
Resistance value: 640 - 720 k ohms
3. If the values are outside the standard values, replace the transaxle range sensor.