Operation CHARM: Car repair manuals for everyone.

Ignition System: Service Precautions


DURASPARK II

Silicone dielectric grease must be applied to all insulating areas of the distributor, spark plug boots, and coil.

When replacing spark plug wires, insure wire made of the same material is used for a replacement. The SS wire is used on cylinders subject to very high engine temperatures.

When removing distributor cap and adapter, always remove the distributor cap first.

Since the electronic control module and ignition coil are on whenever the ignition switch is in the ON or START position, the system will generate a spark whenever the ignition switch is turned off. This may be used as a test tool to check for continuity of circuit, coil and ignition switch. As spark may occur if the distributor cap is removed with switch ON, keep switch OFF during underhood operations until you start the engine or run a test requiring the switch to be on. This will prevent accidental engine rotation.

Maintain a 3/4 inch clearance at distributor cap mounting edge, spark plug wire terminals and coil tower to prevent high voltage arc to ground.

The Duraspark ignition modules are not electrically interchangeable. Duraspark II can be distinguished by having a blue wiring grommet. (Yellow grommet on the Universal Ignition Module.)

When performing diagnostic or service procedures on models equipped with DS II, the ignition switch should remain in the "Off" position unless otherwise stated in the procedure. On these units, a spark will be generated when the ignition switch is placed from the "On" position to "Off", which may inadvertently cause the engine to rotate, resulting in personal injury.