F4 Check For Continuity Along Harness Circuit 599
- Verify ohmmeter is on 200 ohm scale.- Measure resistance between antilock electronic control module harness connector Pin 13 (PK/LG) and RABS valve harness connector Pin 1.
- Is resistance greater than 10 ohms?
YES -- Find and Repair open circuit along Circuit 599 (PK/LG). Go to F7. F7 Clear DTC/Pull DTC
NO -- Circuit is not open. Go to F5. F5 Check For Continuity Along Harness Circuit 274