Operation CHARM: Car repair manuals for everyone.

K10 Measure RABS Sensor Output

- Put vehicle on hoist and raise so that the rear wheels can rotate freely.

- Verify the vehicle is in 4x2 mode and hubs are unlocked.

- Set an AC voltmeter on the 2000mV scale.

- Remove the cap from the RABS sensor test connector and connect the AC voltmeter across the connector leads.

- Start the engine and turn the rear wheels at 5 mph.

- Measure the voltage output of the sensor.

- Do 650mV, or more, register?

Voltage is 650mV (RMS) or greater
Reinstall the RABS sensor test connector cap. Go to K11. K11 Measure RABS Sensor Air Gap

Voltage is less than 650mV (RMS)
Reinstall the RABS sensor test connector cap. Replace RABS sensor. Go to Pinpoint Test S to verify concern is resolved. S Verification Drive Test