Refrigerant System Leak Tests

120 Watt 110 Volt UV Lamp 20 Degree Celsius:






R-134a Automatic Calibration Halogen Leak Detector:






Manifold Gauge Set:






Special Tools

ELECTRONIC LEAK DETECTOR

WARNING: GOOD VENTILATION IS NECESSARY IN THE AREA WHERE A/C LEAK TESTING IS TO BE PERFORMED. IF THE SURROUNDING AIR IS CONTAMINATED WITH REFRIGERANT GAS, THE LEAK DETECTOR WILL INDICATE THIS GAS ALL THE TIME. ODORS FROM OTHER CHEMICALS SUCH AS ANTIFREEZE, DIESEL FUEL, DISC BRAKE CLEANER, OR OTHER CLEANING SOLVENTS CAN CAUSE THE SAME PROBLEM. A FAN, EVEN IN A WELL VENTILATED AREA, IS VERY HELPFUL IN REMOVING SMALL TRACES OF CONTAMINATION FROM THE AIR THAT MIGHT AFFECT THE LEAK DETECTOR.







1. Attach R-134a Manifold Gauge Set to the service gauge port valves.
^ Leave both manifold gauge set valves closed.
^ Both gauges should indicate 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.
^ If little or no pressure is indicated, charge the refrigerant system.







2. Use Halogen Leak Detector R-134a to leak test the refrigerant system. Follow the instructions included with the leak detector for handling and operation techniques.







3. If a leak is found, recover the refrigerant and service the system.

LEAK TRACER DYE

NOTE: Ford Motor Company now produces vehicles with R-134a Leak Tracer Dye incorporated into the A/C system. The exact location of leaks can be pinpointed by the bright yellow-green glow of the tracer dye. Since more than one leak may exist, always inspect each component.







1. Use 120 Watt UV Spot Lamp to check for leaks.
2. Scan all components, fittings, and lines of the A/C system.
3. After the leak is repaired, remove any traces of leak dye with a general purpose oil solvent.