Operation CHARM: Car repair manuals for everyone.

Peanut Fitting

DISCONNECT







1. Remove the nut from the peanut fitting.

CAUTION: Support the female fitting with a wrench to prevent the tubes from twisting.







2. Pull the peanut fitting apart.







3. Remove the O-ring seal with a non-metallic tool.

CAUTION: Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring groove resulting in refrigerant leaks.

CONNECT
1. Clean all dirt or foreign material from the fittings.







2. Install the O-ring seal.
1 Lubricate the O-ring seal with Motorcraft YN-12b refrigerant oil F2AZ-19577-AC (Canada: Motorcraft CYN-12b) or equivalent meeting Ford specification WSH-M1C231-B.

CAUTION: Use only new green O-rings. The use of any O-ring seals other than specified may result in intermittent leakage during vehicle operation.

3. Lubricate the inside of the fittings with Motorcraft YN-12b refrigerant oil F2AZ-19577-AC (Canada: Motorcraft CYN-12b) or equivalent meeting Ford specification WSH-M1C231-B.







4. Assemble the male and female fittings together.

NOTE: When properly assembled the male and female fittings should be flush.