Operation CHARM: Car repair manuals for everyone.

Test C: A Single Power Window Is Inoperative - RH

PINPOINT TEST C: A SINGLE POWER WINDOW IS INOPERATIVE - RH


C1-C3:






C3-C5:






C5-C6:






C6:






Normal Operation
The RH front window control switch (RH front door) receives power from the central junction box (CJB) through circuit 170 (RD/LB) and is grounded through the LH front window control switch. When the RH front window control switch is pressed to the up position, battery voltage is sent to the RH front window regulator motor through circuit 334 (RD/YE) and ground through circuit 333 (YE/RD). The window regulator motor will move the window glass up. When the RH front window control switch is pressed to the down position, battery voltage is sent to the LH front window regulator motor through circuit 333 (YE/RD) and ground through circuit 334 (RD/YE). The window regulator motor will move the window glass down.

RH Front Window Operation From LH Front Switch
When the RH front power window is operated in the up direction from the LH front window control switch, power is sent to the RH front window control switch through circuit 313 (WH/YE), which transfers power to the RH front window motor through circuit 333 (YE/RD). Ground is provided to the RH front window switch through circuit 314 (TN/LB), which transfers ground to the RH front window motor through circuit 334 (RD/YE).

When the RH front power window is operated in the down direction from the LH front window control switch, power is sent to the RH front window control switch through circuit 314 (TN/LB), which transfers power to the front window motor through circuit 334 (RD/YE). Ground is provided to the RH front window switch through circuit 313 (WH/YE), which transfers ground to the RH front window motor through circuit 333 (YE/RD).

Possible Causes
- RH front window motor
- RH front window control switch
- Open in circuits 170 (RD/LB), 314 (TN/LB), 313 (WH/YE), 333 (YE/RD) or 334 (RD/YE)