Programming and Relearning

ROOF OPENING PANEL MOTOR INITIALIZATION

CAUTION: Be sure there are no obstructions in the path of the roof opening panel glass before attempting to initialize the roof opening panel motor.

NOTE:
- A new roof opening panel motor will only open and must be initialized.
- The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel system, including: any time the roof opening panel motor has been removed from the roof opening panel assembly, a new roof opening panel motor has been installed or when a new roof opening panel assembly has been installed.

1. Turn the ignition to the RUN position. For an existing roof opening panel motor, proceed to Step 3.

2. NOTE: If the open switch is released before initialization movements are complete, turn the ignition key to the OFF position, then back to the RUN position and repeat this step.

For a new roof opening panel motor/module:
- Press the open switch until the roof opening panel moves past the full OPEN position and continue to hold for approximately 10 seconds. The roof opening panel will cycle slightly rearward and then slightly forward to the stored OPEN position. Release the switch at this point.
- Press and hold the open switch. The roof opening panel glass will move to the full TILT position, then back to CLOSED (initialization movements). The initialization movements will start within approximately 3 seconds after the switch is pressed. When the initialization movements are complete, go to Step 4.

3. NOTE:
- All roof opening panel motor/module assemblies have an electronically controlled comfort STOP position, which is approximately 50 mm (2 in) from the full OPEN position. When the roof opening panel is opened, the open switch must be released when the comfort STOP position has been reached and then pressed again to fully open the roof opening panel.
- If the open switch is released before initialization movements are complete, turn the ignition key to the OFF position, then back to the RUN position, and repeat this step. For an existing roof opening panel motor/module:
- Press and hold the open switch until the roof opening panel glass moves to the full OPEN position.
- Press and hold the open switch (for approximately 10 seconds) until the roof opening panel glass moves past full OPEN, then back to full OPEN. Quickly release the switch.
- Press and hold the open switch. The roof opening panel glass will move to full TILT, then back to CLOSED (initialization movements). The initialization movements will start within approximately 3 seconds after the switch is pressed.

4. Release the open switch and test the system for normal operation by carrying out one-touch open to comfort STOP, full OPEN, close from full OPEN to full CLOSE and TILT operations.