With Star Tester
Fig. 36 Checking in-line base timing electrical connector connection:
1. Ensure the Inline base timing electrical connector is securely connected, Fig. 36.
2. Start engine. If engine does not start refer to the appropriate Pinpoint Test charts.
3. Depress self-test button on STAR tester. Engine speed should increase. Do not note any codes that appear in the tester display window at this time.
4. Check computed ignition timing as follows:
a. Connect a suitable timing light onto engine as described previously.
b. With the EEC-IV system in the self-test mode, check ignition timing.
c. Ignition timing obtained should be 20° more than the specified base ignition timing.
d. If computed timing is not 20° more than the base timing, refer to the appropriate Quick and/or Pinpoint Test chart procedures.
5. Deactivate the STAR tester by depressing self-test button. The colon should disappear along with any service codes displayed.