Distributor Advance Unit: Service and Repair
1. Remove distributor cap and rotor.
2. Disconnect vacuum lines, then remove snap ring that secures vacuum advance link to pickup assembly.
3. Remove vacuum advance attaching screws, then tilt unit downward to disconnect link.
4. Carefully remove unit from distributor.
5. Reverse procedure to install.