QT4 Equipment Hookup
Use an Analog Volt-Ohmmeter (VOM) Rotunda 059-00010 or equivalent. The VOM needle will pulse from 0 to 12V, indicating a service code which coresponds to the number of pulses. After the equipment is hooked up, proceed to Quick Test Step 5.0A.
1. Turn the ignition key Off.
2. Remove the drivers seat.
3. Connect a jumper wire from the check connector terminal wire "GN/BK" to "BK". Set the VOM on a DC voltage range to read from 0 to 20 volts.
4. Connect to VOM between the "GN/R" terminal on the check connector and the battery neg. terminal.