P2 Verify Integrity of Electronic Control Module Connection
- Turn ignition OFF.- Disconnect battery ground cable.
- Remove the antilock electronic control module harness connector.
- Pull gently on wire just behind Pin 3 on the harness connector.
- Pull gently on wire just behind Pin 10 on the harness connector.
- Is terminal fully engaged?
YES -- Leave antilock electronic control module connector disconnected. Go to P3.
NO -- Service terminal or connector as needed. Go to P7.