E7 Check Circuit 571 Continuity
- Set the voltmeter to the 200 ohm scale.- Disconnect the RABS diagnostic connector from its mating half (Circuits 571 [BK/O] and 483 [R]).
- Measure resistance of Circuit 571 (BK/O) from diagnostic connector to antilock electronic control module harness connector Pin 12.
- Is the resistance less than 20 ohms?
YES -- Replace antilock electronic control module.
NO -- Repair Circuit 571 (BK/O). Reconnect antilock electronic control module. Repeat System Pre-Check. Inspection and Verification (Start Testing Here)