G3 Verify Integrity of RABS Valve Connection
- Remove RABS valve connector.- Inspect RABS valve connector Pin 4.
- Gently pull on Pin 4 wire just behind RABS harness connector.
- Are connections clean and secure?
YES -- Leave RABS valve connector disconnected. Go to G4. G4 Check Continuity Circuit 664 ECM Connector Pins 8 and 14
NO -- terminal(s) in RABS valve connector are loose, bent, deformed, corroded, or missing. Service terminal or connector as needed. If not serviceable, Replace RABS valve. Go to G7. G7 Clear DTC/Pull DTC
NO -- terminal(s) in harness connector move back or come free of connector. Service terminal or connector as needed. Go to G7. G7 Clear DTC/Pull DTC