H1 Check Warning Lights
RABS Valve Mini Schematic:
- Key OFF.
- Locate and disconnect the diagnostic connector from its mating half (Circuits 571 [BK/O] and 483 [R]).
- Reconnect diagnostic connector.
- Key ON.
- Do both the red BRAKE and yellow RABS lamps come on?
YES -- Hard fault. Go to H2. H2 Verify Integrity of Electronic Control Module Connection
NO -- Intermittent fault. Go to Pinpoint Test T T Intermittent Diagnosis and proceed with intermittent diagnosis for all affected circuits. Refer to mini-schematic for this test.