B5 Check Circuit 537 (T/Y) For Ground Short
- Remove main relay.
- Check for ground short on Circuit 537 (T/Y) between 30A fuse and relay connector.
- Is a ground short detected?
YES -- Service as required. Go to B14. B14 Verify Concern Is Resolved
NO -- Go to B6. B6 Check Circuit 532 (O/Y) For Ground Short