E5 Check Power to the Antilock Electronic Control Module
- Turn the ignition to the ON position.- Measure the voltage between RABS antilock electronic control module harness connector Pin 1 (or Pin 9) and chassis ground.
- Is voltage greater than 9 volts?
YES -- Leave antilock electronic control module disconnected. Go to E6.
NO -- Repair Circuit 601 (LB/PK) or associated fuse. Reconnect antilock electronic control module. Repeat System Pre-Check.