Manufacturer Code Charts: 7: 7.2
- Remove RABS valve connector.
- Inspect RABS valve component connector and Pins 1 and 3.
- Are connections clean and secure?
YES -- Circuit is not shorted. Leave RABS valve connector disconnected. GO to 7.3. 7.3
NO -- Service terminals or connector as needed. If not serviceable, Replace RABS valve. Go to 7.6. 7.6