Manufacturer Code Charts: 7: 7.5
- This step requires that a valid diagnostic trouble code has been obtained, all prior diagnostic steps have been completed, and the affected wiring integrity has been verified.
CAUTION: Make sure to complete all steps. Failure to do so could lead to replacement of good parts.
- Have all prior diagnostic steps been completed as described above?
YES -- Replace anti-lock electronic control module. Go to Step 7.6. 7.6
YES -- If anti-lock electronic control module has been replaced and no resolution has been reached, Replace RABS valve. Go to Step 7.6. 7.6
NO -- Go to diagnostic step last completed and continue.