Door Lock Switch
Component TestsSwitch, Door Lock
Using a self-powered test light or volt ohmmeter, there should be no continuity between any terminals with the switch in its normal neutral position.
Continuity should exist between terminals 1 and 2 with the switch held in the LOCK position and between terminals 2 and 3 with the switch held in the UNLOCK position.