Quick Test 2.0 - Set Up
NOTE: Perform all necessary servicing before continuing with Quick Tests.
Connect Rotunda New Generation Star (NGS) Tester 007-00500 or equivalent to Data Link Connector (DLC).
The following are procedures to run OBD II procedures.
Prepare the vehicle as follows:
- Place transaxle range selector lever in PARK.
- Warm engine to operating temperature.
- Apply parking brake.
- Block wheels.
- Turn off all electrical loads including A/C and defroster. (If A/C is on, DTC P1460 will set.)
Prepare the NGS as follows:
- Turn ignition switch OFF.
- Verify that the proper PROGRAM card is inserted in the NGS.
- Connect J1962/ 16 way data communication link (DCL) cable adapter to the NGS.
- Connect NGS DCL cable adapter securely into the vehicle's DCL connector.
- Connect the NGS power supply cable to the vehicle battery power supply through cigarette lighter or at the battery with alligator clip adapter.
- Turn the ignition switch to RUN, or start vehicle if necessary.
- The NGS is now ready to communicate with the powertrain control module.
CAUTION: Do not replace parts based on a code. Perform pinpoint test first.
Other NGS Testing Features
Other diagnostic methods include the following:
- Parameter Identification (PID) Access Mode, used to monitor sensors and actuators.
- Freeze Frame Data Access Mode, used to view emission related data values from specific PIDs.
- Oxygen Sensor Monitor Mode, used to monitor the 02 sensor.