Protective Device
- 30 Amp. Fuse in Blower Circuit Brown - Orange
- 15 Amp. Fuse in Clutch Circuit White - Purple
- Thermal Limiter in Blower Resistor Circuit (Integral With Resistor)

Blower Speed Current Draw (Maximum)
Low 3.6 Amps
Med. Low 6.3 Amps
Med. High 9.7 Amps
High 14.1 Amps


Blower Speed Voltage Drop
Low 4.1-5.6 Volts
Med. Low 6.4-7.9 Volts
Med. High 8.7-10.2 Volts
High 11.3-12.8 Volts