Compressor Fitting HVAC: Service and Repair
REMOVAL1. Recover refrigerant from system. Refrigerant Recovery
2. Remove bolt attaching A/C manifold and tube to A/C compressor, and remove A/C manifold and tube and O-ring seals.
INSTALLATION
1. Lubricate new O-ring seals with clean refrigerant oil and position them in O-ring seal grooves of A/C manifold and tube.
2. Position A/C manifold and tube with O-ring seals to A/C compressor and install and tighten the retaining bolt.
3. Connect other ends of suction and discharge lines using new lubricated O-ring seals.
4. Leak-test, evacuate, and charge system following recommended procedures. Observe all safety precautions. Service and Repair