M4
M4 CHECK CIRCUIT 664 (Y/LG)RABS Valve Circuit Resistance Check:
- Measure the resistance between the anti-lock electronic control module C222-14, circuit 664 (Y/LG) and the RABS valve connector pin 1, circuit 664 (Y/LG).
- Is the resistance less than 5 ohms?
> Yes
Repeat System Pre-Check. Initial Inspection and Diagnostic Overview
> No
Repair circuit 664 (Y/LG). Repeat System Pre-Check. Initial Inspection and Diagnostic Overview