Pressure Regulating Solenoid: Testing and Inspection
DESCRIPTIONThe electronic pressure control (EPC) solenoid regulates transmission EPC pressure. EPC valve pressure is used to control line pressure and the 2-3 backout valve function.
SYMPTOMS
^ Failed ON- Minimum EPC pressure (minimum capacity), limit engine torque (alternate firing).
^ Failed OFF- Maximum EPC pressure, harsh engagements, harsh shifts.
DTC's
P1746*, P1747*