Hose/Line HVAC: Description and Operation
NOTE: Whenever a refrigerant line is replaced, it is also necessary to replace the suction accumulator/drier.The front condenser to evaporator tube contains high pressure liquid refrigerant. It has the following features:
- a fitting used to mount the A/C pressure transducer. A long-travel Schrader-type valve stem core is installed in the fitting so that the A/C pressure transducer can be removed without discharging the A/C system.
- a fitting used to mount a serviceable high-pressure A/C charge port valve.
The rear condenser to evaporator tube contains the A/C evaporator core orifice. When the A/C system is in operation:
- there is high pressure liquid refrigerant upstream of the A/C evaporator core orifice.
- there is low pressure liquid refrigerant downstream of the A/C evaporator core orifice.
The A/C manifold and tube is attached to the A/C compressor with O-ring seals and has the following features:
- the upstream side contains low pressure refrigerant gas and serviceable low-pressure A/C charge port valve.
- the downstream side contains high pressure refrigerant gas and an integral non-serviceable muffler.