Operation CHARM: Car repair manuals for everyone.

RAP Module






The RAP module sends a signal to the GEM on the illuminated entry request circuit to indicate a request to turn the illuminated entry feature on or off. Circuit 1013 (BR/LG) is normally sent 12 volts by the GEM. The RAP module shorts this circuit to ground with a pulse of either of the following lengths:
^ 200 ms pulse from RAP receiver assembly requests illuminated entry ON (unlock button pressed).
^ 300 ms pulse from RAP receiver assembly requests illuminated entry OFF (lock button pressed).