Countershaft Bearing
Special Tools:
Disassembly
1. NOTE: With the exception of the bearings the countershaft is serviced as an assembly.
NOTE: This procedure is used for both countershaft bearings.
2. Use the Collets and Forcing Screw to remove the output shaft bearing.
Assembly
1. CAUTION: Do not heat the countershaft shaft bearings for more than 15 minutes.
Use a Gear/Bearing Heater to heat the countershaft bearing to 130°C (250°F).
2. Install the output shaft bearing until it seats against its stop.