Operation CHARM: Car repair manuals for everyone.

Exhaust Back Pressure Valve

Spring Gauge:






SPECIAL SERVICE TOOL(S)

REMOVAL
1. Open the hood.
2. Remove the charge air cooler inlet and outlet ducts from the compressor manifold.







3. Disconnect the exhaust outlet pipe from the turbocharger.
1 Loosen the clamp.
2 Pull the exhaust pipe away from the exhaust back pressure valve.







4. Disconnect the exhaust back pressure valve.
1 Slide the retaining clip toward the turbocharger housing.
2 Disconnect the exhaust back pressure valve actuator rod from the exhaust back pressure valve.







5. Remove the six bolts and the exhaust back pressure valve.

INSTALLATION







1. Follow the removal procedure in reverse order.







2. Using the Spring Gauge, adjust the actuator rod length to obtain the specified reading.