Expansion Block/Orifice Tube: Service and Repair
SPECIAL SERVICE TOOL(S)
REMOVAL
1. Remove the condenser to evaporator tube; refer to Line-Condenser to Evaporator.
^ For a fixed orifice tube, perform Steps 2 and 3.
^ For a broken orifice tube, perform Steps 4 and 5.
2. Engage the Fixed Orifice Tube Remover/Replacer to the A/C evaporator core orifice.
3. Hold the tool T-handle stationary and rotate the tool body to remove the A/C evaporator core orifice.
4. Screw the end of the Broken Orifice Tube Extractor into the broken A/C evaporator core orifice.
5. Hold the tool T-handle stationary and rotate the tool body to remove the broken A/C evaporator core orifice.
INSTALLATION
1. Lubricate and install the O-ring seals on the A/C evaporator core orifice.
^ Use Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.
2. Place the A/C evaporator core orifice into the Fixed Orifice Tube Remover/Replacer.
3. Insert the A/C evaporator core orifice into the condenser to evaporator tube until seated.
4. Remove the Fixed Orifice Tube Remover/Replacer.
5. Install the condenser to evaporator tube; refer to Line-Condenser to Evaporator.