Compressor HVAC: Service Precautions

CAUTION: To prevent refrigerant system contamination if you are installing a new A/C compressor which has failed internally, you must carry out the following procedures:
^ If special tool A/C Flusher 014-00991 or equivalent is available, carry out the Flushing general procedure.
^ If special tool A/C Flusher 014-00991 or equivalent is not available, carry out the Refrigerant System Filtering after A/C Component Replacement general procedure.
^ Installation of a new suction accumulator/drier is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator/drier. For additional information, refer to Suction Accumulator.
^ Install a new A/C evaporator core orifice. For additional information, refer to Evaporator Core Orifice.