Initial Inspection - Instrument Panel Illumination
NOTE: Upon installation of a new instrument cluster, the module must be reconfigured.1. Verify the customer concern by operating the instrument illumination.
2. Visually inspect for obvious signs of electrical damage; refer to the chart.
VISUAL INSPECTION CHART
Electrical
^ Battery Junction Box (BJB) Fuse 6 (15A)
^ Central Junction Box (CJB) Fuse 18 (5A)
^ Wiring harness
^ Headlamp switch
3. If the fault is not visually evident, determine the symptom and proceed to the Symptom Chart. Diagnosis By Symptom - Instrument Panel Illumination