Dual Converter Y-Pipe
Dual Converter Y-PipeRemoval and Installation
1. Remove the dual three-way catalytic converter.
2. Disconnect the heated oxygen sensors.
3. Remove the LH nuts.
4. Remove the RH nuts and remove the dual converter Y-pipe.
5. Remove the converter inlet gasket and, necessary, the heated oxygen sensors.
^ Discard the gasket.
6. CAUTION: Make sure that the dual converter Y-pipe to exhaust manifold nuts are tightened after the three-way catalytic converter is installed.
NOTE: Make sure to apply anti-seize lubricant to the threads of the sensors before installation.
To install, reverse the removal procedure.