| Type C II | Flow rate @ 74 degrees-80 degrees C(165 degrees -175 degrees F) and engine set at 1500 RPM | 2.2-2.6 gpm |
| Maximum pressure @ 74 degrees-80 degrees C (165 degrees-175 degrees F) and engine speed set at 1500 RPM | 150 psi |
| Minimum flow rate@ 74 degrees-80 degreesC(165 degrees-175 degrees F), 5102 KPA (750 PSI) and engine speed set at idle | 0.95 gpm |
| Relief pressure | 1,300-1,480 psi |
| Type C III | Flow rate @ 74 degrees -80 degrees C (165 degrees-175 degrees F) and engine set at 1500 RPM | 2.2-2.6 gpm |
| Maximum pressure @ 74 degrees-80 degrees C (165 degrees-175 degrees F and engine set at 1500 RPM | 150 psi |
| Minimum flow rate @ 74 degrees-80 degrees C(165 degrees-175 degrees F), 5102 KPA (750 psi) and engine speed set at idle | 1.4 gpm |
| Relief pressure | 1,400-1,530 psi |