Single Generator

GENERATOR - SINGLE GENERATOR

REMOVAL

NOTE: This procedure also applies to the primary generator of the dual generator system.

1. Disconnect the dual batteries.







2. Position the cowl wire harness aside.
1 Remove the bolt and position the manifold absolute pressure (MAP) sensor aside.
2 Remove the bolt and position the ground strap aside.
3 Remove the 2 bolts and position the power steering fluid reservoir aside.
4 Remove the 3 bolts and position the cowl wire harness aside.







3. Remove the 3 bolts, 2 nuts and the intercooler tube bracket.







4. Loosen the 2 clamps and remove the intercooler tube.
5. Rotate the accessory drive belt tensioner clockwise and remove the drive belt from the generator pulley.
6. Remove the transmission dipstick tube bracket nut from the generator stud bolt and position the bracket aside.







7. Remove the generator.
1 Position the rubber cover aside, remove the nut and disconnect the B+ electrical connector.
2 Disconnect the generator electrical connector.
3 Remove the 2 stud bolts and 1 bolt.

INSTALLATION

1. NOTE: Make sure to install the engine-to-body ground strap under the front generator stud bolt.

To install, reverse the removal procedure.