Operation CHARM: Car repair manuals for everyone.

Test E: An Individual Interior Lamp Is Inoperative

PINPOINT TEST E: AN INDIVIDUAL INTERIOR LAMP IS INOPERATIVE


E1-E2:






Normal Operation
Circuit 1005 (VT/OG) provides voltage to each interior lamp when activated. The interior lamps are grounded through circuit 401 (PK). The battery saver in the SJB deactivates the voltage and ground circuits after time-out.

Possible Causes
- circuit 1005 (VT/OG) open
- circuit 401 (PK) open
- lamp assembly