Test N: The LH Turn Indicator Is Never On

PINPOINT TEST N: THE LH TURN INDICATOR IS NEVER ON


N1-N3:






Normal Operation
When the multifunction switch is placed in the LH turn signal position, voltage is supplied to the instrument cluster through circuit 3 (LG/WH). When the instrument cluster receives the voltage signal, it grounds circuit 3 (LG/WH), illuminating the LH turn indicator.

Possible Causes
- circuit 3 (LG/WH) open
- instrument cluster