Test C: The Air Conditioning (A/C) Is Inoperative
PINPOINT TEST C: THE AIR CONDITIONING (A/C) IS INOPERATIVEC1:
C2-C5:
C5-C8:
C8-C10:
C10-C12:
C12-C14:
C14-C16:
C16-C18:
Normal Operation
Under normal operation, the A/C system is activated when the function selector switch is in the NORMAL A/C, MAX A/C, FLOOR/DEFROST or DEFROST modes. The PCM controls the cycling of the A/C compressor clutch.
Possible Causes
- Fuse
- Circuit 57 (BK) open
- Circuit 198 (DG/OG) open or short to ground
- Circuit 321 (GY/WH) open
- Circuit 331 (PK/YE) open
- Circuit 347 (BK/YE) open or short to power
- Circuit 348 (VT) open or short to ground
- Circuit 361 (RD) open
- Circuit 441 (RD/YE) open or short to ground
- Circuit 570 (BK/WH) open
- Circuit 883 (PK/LB) open
- A/C cycling switch
- Dual pressure switch
- A/C clutch solenoid
- A/C compressor clutch
- A/C clutch relay
- PCM
- Function selector switch