Test Q: The RH Turn Indicator Is Never On

PINPOINT TEST Q: THE RH TURN INDICATOR IS NEVER ON


Q1-Q4:






Normal Operation
The RH turn indicator bulb receives voltage through circuit 2 (WH/LB) when the multifunction switch is placed in the RH turn signal position. The RH turn indicator bulb is grounded through the instrument cluster ground circuit 57 (BK).

Possible Causes
- circuit 2 (WH/LB) open
- circuit 57 (BK) open