Test G: Incorrect/Erratic Direction of Air Flow From Outlet(s) - Manual Climate Control
PINPOINT TEST G: INCORRECT/ERRATIC DIRECTION OF AIR FLOW FROM OUTLET(S) - MANUAL CLIMATE CONTROLG1-G3:
G3-G5:
G5-G7:
G7-G9:
G9-G10:
G11-G13:
G13-G14:
G15-G17:
G17-G18:
G19-G20:
Normal Operation
Under normal operation, the function selector switch is provided vacuum from the engine. When a position is selected, vacuum is applied to the desired vacuum control motor that is connected to the mode door you want to control.
Possible Causes
- Fuse
- Function selector switch
- Heater control valve
- Vacuum control motor
- Stuck or bound linkage or door
- Leaking or plugged vacuum hose