Test R: The Blower Motor Does Not Operate Correctly - EATC
PINPOINT TEST R: THE BLOWER MOTOR DOES NOT OPERATE CORRECTLY - EATCR1-R3:
R3-R5:
R5-R7:
R7-R8:
Normal Operation
The blower motor control module receives a 1-2 volt signal from the electronic automatic temperature control (EATC) module through circuit 754 (LG/WH) to determine the desired blower motor speed. The EATC module receives a feedback voltage from the blower motor control module through circuit 752 (YE/RD) to determine actual blower motor speed. When the highest blower motor setting is selected, the EATC module sends 12 volts to the blower control module through circuit 261 (OG/BK)/751 (DB/WH).
Possible Causes
- An open, short to voltage, ground or together in circuits 261 (OG/BK), 751 (DB/WH) or 752 (YE/RD)
- Blower motor control module
- Electronic automatic temperature control (EATC) module