Test G: One Or More Stoplamps Are Inoperative
PINPOINT TEST G: ONE OR MORE STOPLAMPS ARE INOPERATIVEG1-G2:
G2-G4:
G5-G7:
G7-G10:
Normal Operation - Except STX
The smart junction box (SJB) provides voltage to the stoplamp switch through circuit 10 (LG/RD). When the brake pedal is applied, the voltage is routed to the high mounted stoplamp and the multifunction switch through circuit 511 (LG). The multifunction switch then routes the voltage to the LH and RH rear lamps through circuits 9 (LG/OG) and 5 (OG/LB), respectively. Ground for the stoplamps is provided through circuit 57 (BK).
Normal Operation - STX
The SJB provides voltage to the stoplamp switch through circuit 10 (LG/RD). When the brake pedal is applied, the voltage is routed to the high mounted stoplamp and the rear lamps through circuit 511 (LG). Ground for the stoplamps is provided through circuit 57 (BK).
Possible Causes
- Fuse
- Circuit 5 (OG/LB) open
- Circuit 9 (LG/OG) open
- Circuit 10 (LG/RD) open
- Circuit 57 (BK) open
- Circuit 511 (LG) open
- Stoplamp switch
- High mounted stoplamp
- Multifunction switch
- SJB