Blower Motor
BLOWER MOTORRemoval and Installation
NOTE: The blower motor vent tube must be completely removed from the blower motor before it can be rotated and disengaged from the heater core and evaporator core housing.
1. Remove the RH lower instrument panel insulator (if equipped).
2. Remove the RH lower A-pillar junction box cover.
3. Position the carpet below the blower motor aside.
4. Release the 2 blower motor vent tube clips and remove the blower motor vent tube.
5. Disconnect the blower motor electrical connector.
6. NOTE: The blower motor will have to be carefully manipulated along the dash panel insulator, and the dash panel insulator will have to be slightly deflected to allow the blower motor to clear the heater core and evaporator core housing.
Rotate the blower motor counterclockwise to disengage it from the housing and remove the blower motor.
7. To install, reverse the removal procedure.